From breakers that trip mid-service to hood interlocks that fail inspection, these are the calls we get most often from restaurant owners.
A breaker that trips consistently during the busiest hour of service points to a load calculation problem, not a defective breaker. Multiple appliances drawing at once are pushing a circuit past its rated capacity. We run a full load calculation and separate overloaded circuits onto dedicated branches.
A cooler sharing a circuit with cooking equipment can lose power the moment other appliances spike demand during service. This puts refrigerated inventory at risk of failing a health inspection. We wire refrigeration onto its own dedicated circuit so it stays protected regardless of what else is running.
Exhaust hoods must be electrically interlocked with the cooking equipment beneath them under NFPA 96, and a failed test at inspection can delay an opening by weeks. This is often caused by wiring done without coordinating with the hood manufacturer's specifications. We coordinate directly with the hood and fire suppression contractor to get the interlock right the first time.
Full-service kitchens running combi ovens or wok ranges typically need three-phase power, and single-phase supply cannot handle that load. Discovering this mid-construction adds weeks of delay and unplanned cost. We assess the building's incoming service early and flag a utility upgrade before it becomes a surprise.
Adding a new fryer, oven, or prep station often reveals a panel with no spare capacity for another dedicated circuit. This is a common surprise during a menu expansion or equipment upgrade. We assess panel capacity and add circuits or a subpanel to support the new equipment.
Commercial kitchens require GFCI protection on 125-volt, single-phase, 15- and 20-amp receptacles, and health inspectors check for this specifically. Missing or non-functional GFCI protection is a common reason inspections get delayed. We install and test every required GFCI point as part of a wiring project.
Prep areas and dish pits see heavy moisture exposure, and exposed cable in these zones degrades quickly and can fail an inspection. Kitchen wiring in wet zones needs metal conduit rated for physical protection. We route and protect wiring specifically for the moisture level of each zone in the kitchen.
Ordering equipment before an electrician assesses the space often reveals a panel or service gap mid-construction, which can push back an opening date by weeks. Catching this early avoids the most expensive kind of delay. We assess load requirements during the design phase, before equipment orders lock in a scope that the panel cannot support.
A makeup air unit that fails to activate alongside the exhaust hood creates negative pressure that can pull combustion gases back into the kitchen. This interlock is often overlooked during a rushed pre-opening walkthrough. We test the makeup air interlock alongside the hood controls, not just the hood on its own.
Our cooler kept tripping the breaker every Friday night and we lost product twice before calling Angus Electrical Services. They found the whole line was on one shared circuit. Rewired it properly and we have not had a single trip since.
We were three weeks from our grand opening when they flagged that our building only had single-phase service for the load we needed. Not what we wanted to hear but it saved us from a much worse problem after opening.
The utility upgrade took longer than expected because of scheduling on their end, not ours, but the Angus Electrical Services crew kept us informed the whole way and the final wiring passed inspection on the first try.
Our previous contractor never wired the hood interlock correctly and it failed our fire marshal inspection twice. Angus Electrical Services coordinated directly with our hood manufacturer and fixed it in one visit.
We had a complete gut renovation and they worked directly with our general contractor on the whole electrical scope. Every circuit was labeled clearly and nothing had to be redone after the fact.
They walked our whole equipment list before giving us a number and explained exactly what was driving the cost. Nothing changed once the work actually started, which was a relief after a bad experience with a different company years ago.

A short conversation usually narrows it a long way. We will tell you honestly whether it needs attending today or can be booked for a time that suits.
Access, the board and the actual load all change the price, and none of them can be judged over the phone. The survey costs nothing and it is what makes the figure hold.
The same electrician who priced it carries it out, so nothing is lost between the quote and the day. The site is covered before anything is opened.
Circuits tested under load, the board labelled, the inspection booked and the certificate in your hand. Our labour carries a two-year warranty.
Call Angus Electrical Services about panels, rewiring, chargers or standby power anywhere in Angus, including outside normal hours.
Out-of-hours calls reach an electrician who can tell you whether it waits until morning or not. That answer is free.